GC9310 GAS CHROMATOGRAPH

  • Description
Product Detail

    INTRODUCTION:

    Display: LCD

    Interface: RS232 serial interface and USB interface

    Power Supply: 110/220 VAC, 50-60±1Hz

    Detector: FID, ECD, TCD, NPD, FPD

    Column: packed column, capillary column

    Workstation Version: English

    Dimensions: 800 × 650 × 570 mm

    N.W.: 65Kg

    Packing Dimensions: 800×650×570mm

    G.W.: 80Kg

    Packing: Wooden Box


    MAJOR APPLICATION FIELDS:

    Building Indoor Environment Testing (Benzene, toluene, xylene, TVOC, NMTHC)

    Natgas, Artificial Gas, Coal-Mine Gas, LPG, Mixed Gas, High Purity Gas (Ar, He, O 2 , N 2 , CO 2 )

    Food Additives & Pesticide Residue (organophosphorus, organochlorine, amino acid methyl ester )

    Alcohol & Liquor (methanol, ethanol, ethyl acetate, ethyl butyrate, acetaldehyde)

    Dissolved Gas (hydrogen, methane, ethane, ethylene, acetylene, carbon monoxide, carbon dioxide)

    Petrochemical Testing and Fine Chemicals (crude oil, gasoline, essence)


    FEATURES:

    ? GC9310 gas chromatograph control circuit using micro-processing systems and man-machine conversation menu with real-time display of all

    parameters, setting values and actual values.

    ? GC9310 gas chromatograph can be installed packed column and capillary column, with column automatic cooling, automatic rear door

    opening and pressure displaying functions.

    ? GC9310 gas chromatograph using a double stable pneumatic system, single packed column structure and a separate set of capillary shunt

    valve, it can be installed capillary flow, and could be installed hydrogen and air flow in different carrier gas, these separate ways can be adjusted

    independently.

    ? GC9310 gas chromatograph column with microcomputer temperature control system and excellent anti-interference, anti-temperature

    overshoot ability, column, sampler, TCD and capillary injector can be used for wide temperature range and high precision temperature control,

    the column oven temperature can be programmable to five-stage heat up. It can also microcomputerized the FID amplifier range and polarity

    selection, TCD current settings and display.

    ? GC9310 gas chromatograph also has a temperature limit setting, analysis time count, temperature kepting, dynamic scan the actual

    temperature, opens the rear door automatically when cooling the column box, power data protection.


    MAJOR SPECIFICATIONS AND FUNCTION:

    Column Box

    Temperature

    Control

    Temperature Range RT 5°C~399°C(Incremental 1°C)
    Temperature AccuracyBetter than±0.1°C(200°C)
    Temperature-programmed magnification10
    Temperature-programmed rate setting

    0.1°C~40°C/min(Incremental 1°C)(1°C -200°C)

    25°C/min(Incremental 1°C)(above 200°C)

    Magnification temperature time0~655min(Incremental 1min)
    Temperature object column box, detectors, samplers
    TCDSensitivity =3000mv.ml/mg
    Baseline noise=20µv
    Baseline draft =50µv/30min
    Gas flow rate stability=1%
    High sensitivity TCD=6000mv.ml/mg
    FIDDetection limit =8×10 -12 g/s
    Baseline noise =5×10 -14 A
    Baseline draft =2×10 -13 A/30min

    Temperature

    (sampler,FID,TCD)

    Stabilization time 30min
    Temperature Range RT 5°C~399°C(Incremental 1°C)
    Temperature AccuracyBetter than ±0.1°C(200°C)


Send your message to this supplier